cbrn:CountDoseData
The measurement data from a count dose-capable encounter device.
Element information
Namespace: http://niem.gov/niem/domains/cbrn/2.1
Schema document: domains/cbrn/2.1/cbrn.xsd
Type: cbrn:CountDoseDataType
Properties: Global, Qualified, Nillable
Content
- Sequence [1..1]
- cbrn:RemarkText [0..*] General comments or remark.
- cbrn:DetectorDesignatorText [0..*] A description of the detector used to produce a measurement. Must use naming convention defined in the relevant specification document.
- cbrn:DetectorKindText [0..*] Identification of the detector that collected the measurement. Must use naming convention defined in the relevant specification document.
- cbrn:LiveTimeDuration [0..*] Effective time duration of a measurement in ISO 8601 format.
- cbrn:RadCountRateValues [0..*] A list of count rate values from a radiation dose rate detector.
- cbrn:RadCountValues [0..*] A list of raw counts from a radiation dose rate detector.
- cbrn:RadDoseRateValues [0..*] A list of radiation dose rate values presented in dose units per hour (e.g. rem/hr, Sv/hr).
- cbrn:RadTotalDoseValues [0..*] A list of total (accumulated) radiation dose values.
- cbrn:RadAbsorbedDoseRateValues [0..*] A list of radiation absorbed dose rate values presented in absorbed dose units per hour (e.g. rad/hr, mGy/hr).
- cbrn:RadTotalAbsorbedDoseValues [0..*] A list of total (accumulated) radiation absorbed dose values.
- cbrn:RadExposureRateValues [0..*] A list of radiation exposure rate values presented in exposure units per hour (e.g. R/hr, uR/hr).
- cbrn:RadTotalExposureValues [0..*] A list of total (accumulated) radiation exposure values.
- cbrn:RefCalibrationSpectrumID [0..*] Reference to a calibration spectrum. There is no required format for the ID value.
Attributes
Name | Occ | Type | Description | Notes |
---|---|---|---|---|
s:id | [0..1] | xsd:ID | from type s:ComplexObjectType | |
s:metadata | [0..1] | xsd:IDREFS | from type s:ComplexObjectType | |
s:linkMetadata | [0..1] | xsd:IDREFS | from type s:ComplexObjectType | |
cbrn:calibrationMeasurementUUID | [0..1] | xsd:string | ||
cbrn:dataQualityCode | [0..1] | cbrncl:DataQualityCodeSimpleType |
Used in
- Type cbrn:RadEncounterDeviceRawDataType (Element cbrn:RadEncounterDeviceRawData)
Sample instance
<cbrn:CountDoseData> <cbrn:RemarkText>string</cbrn:RemarkText> <cbrn:DetectorDesignatorText>string</cbrn:DetectorDesignatorText> <cbrn:DetectorKindText>string</cbrn:DetectorKindText> <cbrn:LiveTimeDuration>P1Y2M3DT10H</cbrn:LiveTimeDuration> <cbrn:RadCountRateValues>1.0 1.0</cbrn:RadCountRateValues> <cbrn:RadCountValues>1 1</cbrn:RadCountValues> <cbrn:RadDoseRateValues>1.0 1.0</cbrn:RadDoseRateValues> <cbrn:RadTotalDoseValues>1.0 1.0</cbrn:RadTotalDoseValues> <cbrn:RadAbsorbedDoseRateValues>1.0 1.0</cbrn:RadAbsorbedDoseRateValues> <cbrn:RadTotalAbsorbedDoseValues>1.0 1.0</cbrn:RadTotalAbsorbedDoseValues> <cbrn:RadExposureRateValues>1.0 1.0</cbrn:RadExposureRateValues> <cbrn:RadTotalExposureValues>1.0 1.0</cbrn:RadTotalExposureValues> <cbrn:RefCalibrationSpectrumID>string</cbrn:RefCalibrationSpectrumID> </cbrn:CountDoseData>